Water Heater Maintenance and Repair
Hot water system clues
Hot water system clues

Servicing a hot water system means we test its valves, check the tank and its connections for leaks, and replace worn parts before they fail. A repair visit is for the day something goes wrong, such as cold showers or water under the tank.

Hot water system key facts

  • Hot water systems are generally recommended to be serviced every five years by an appropriately licensed person. Bore or rainwater supplies may need it more often.
  • Home owners and tenants may operate the temperature and pressure relief valve themselves, taking care to avoid scalding and to close it properly.
  • Rheem’s owner’s guide for one electric range calls for the relief valve lever to be raised and lowered gently every six months. If water doesn’t flow freely, the heater must be checked.
  • A temperature control device must be fitted to all new and replacement hot water systems. Its purpose is hot water delivered to taps at a maximum of fifty degrees, and a guideline sets where a device is required.
  • Replacing a hot water system is notifiable work under the Plumbing and Drainage Regulation, so the plumber lodges a Form 4.
  • Only a licensed gasfitter can carry out gas work, including servicing and repairing.

When the hot water system needs a plumber

  • No hot water, or cold showers after a storm or a power cut.
  • A steady trickle from the relief valve drain pipe, often heaviest overnight.
  • Nothing comes out of that drain pipe when you lift the relief valve lever.
  • Water in the tray under the tank, or a damp floor around it.
  • Drips from the tempering valve or a fitting on the pipes in and out.
  • On a gas system, a pilot that won’t stay lit, or a smell of gas.

How a storage system works, and where it fails

Cold water at mains pressure pushes in at the bottom, and hot water leaves from the top. As water heats it expands, and the relief valve on the tank lets that extra volume out through a drain pipe. Rheem puts that normal discharge at about one fiftieth of the hot water used.

The relief valve is the safety device. If the thermostat fails and the water overheats, or pressure climbs too high, the valve opens. A valve that dribbles now and then while heating is doing its job. Steady flow for long periods, often at night, may mean mains pressure sometimes rises above the heater’s design pressure. A valve that won’t flow when the lever is lifted may be blocked with deposits, which is why the lever needs regular exercise.

Inside the tank, a sacrificial anode corrodes in place of the steel. Once it’s used up, the tank itself starts to rust. Rheem’s major service for one electric range inspects the anode, and if it’s left in, it’s due for replacement within three years. A leak through the wall of the tank can’t be repaired, and that means a new system.

No hot water has its own set of causes. On an electric system, a power cut or a tripped circuit leaves the water cold. The element and thermostat are electrical equipment, and repairing electrical equipment is work for a licensed electrician. On gas, servicing and repairing are for a licensed gasfitter. We check the supply first, then each part in turn.

Service and repair, compared

Major service Repair Replacement
When On the maker’s schedule; generally recommended five-yearly When something fails Tank leaking, or repair not worthwhile
Typical work Rheem’s electric range: new relief valve, anode inspected, expansion valve flushed Element, thermostat, valve or pilot replaced New system, temperature control device where required
Who Licensed plumber; licensed gasfitter for gas parts; licensed electrician for electrical parts Licensed plumber; licensed gasfitter for gas parts; licensed electrician for electrical parts Licensed plumber, with a solar and heat pump endorsement where needed
Paperwork Service record Record of the part replaced Form 4; gas compliance certificate for a gas installation

What makes a hot water job bigger or smaller

  • A tank in an open laundry or outside wall is quick to reach. One squeezed into a cupboard is slow.
  • A solar tank on the roof brings working at height into it.
  • No isolating valve on the cold pipe means the whole house goes off, and one may need fitting first.
  • A leaking tank turns a repair into a replacement.

Hot water systems in Moreton Bay

Older Moreton Bay homes may have no pressure limiting device, since Unitywater ties them mainly to houses built after two thousand and six. Long spells of steady relief valve flow are linked to mains pressure climbing past what the heater is designed for. So in an older house with a running relief valve, we check the incoming pressure before blaming the valve. Storm season matters too: southern Queensland’s highest severe thunderstorm risk runs from October to December, and the storm question below covers a cold system afterwards.

What to know before we arrive

The legal position comes first. Under the Plumbing and Drainage Regulation, maintaining or repairing an apparatus is minor work for a licensed plumber, and the Plumbing and Drainage Act counts the heater in a hot water system as an apparatus. Replacing one is notifiable work: we lodge a Form 4 with the QBCC and give you, the owner, a copy. Solar and heat pump systems must be installed by a plumber with a solar and heat pump endorsement, shown on the back of the licence card. Anything on the gas side is gas work, which only a licensed gasfitter may do, and electrical parts need a licensed electrician.

At a service we exercise the relief valve. We lift the lever gently, let water run from the drain, then lower it gently so the valve seats again. The water is scalding, so we stand clear. If nothing flows, or water keeps running once the lever is lowered, the valve needs replacing. We look in the tray under the tank and around each fitting. If the water has gone cold, it helps to note whether the power went off anywhere else in the house, and tell us when you call.

The thermostat and the tempering valve stay as they are unless a fault is found, and every cover stays in place until the system is isolated. The relief valve drain is never capped or plugged. Queensland’s Plumbing and Drainage Act also provides that, unless authorised, nobody may remove a temperature control device or make it inoperable. If water is pouring from the tank while you wait for us, close the cold water isolation valve on the pipe going in, if you can reach it safely. Then keep clear of any wet wiring, and call.

If you smell gas, light nothing, leave electrical switches as they are, and open doors and windows. Queensland’s gas safety steps then end with a call to triple zero if the smell stays.

Handy to have when you call:

  • The make, model and age from the label on the tank.
  • Whether it’s electric, gas, solar or heat pump.
  • What happens when you lift the relief valve lever.
  • Whether the power went off, or anything else stopped working.
  • Where the tank sits and how easy it is to reach.

A finished service leaves the relief valve opening and reseating cleanly, the drain clear and no fittings weeping. You are told the anode’s condition. A replacement leaves a temperature control device where the guideline requires one, and a copy of the Form 4. A new gas installation also comes with a gas system compliance certificate, which goes to the owner.

A slow drip from the relief drain needs a booked visit, so we can check the valve and the pressure. A smell of gas, water pouring from the tank, or a relief valve that won’t stop after the lever is lowered needs action now.

Back to the law to finish: servicing and repair must be done by a licensed plumber, and replacement is notifiable work with a Form 4. Gas parts belong to a licensed gasfitter, electrical parts to a licensed electrician.

Hot water terms you’ll hear

  • Temperature and pressure relief valve: the safety valve on the tank that opens if heat or pressure gets too high.
  • Expansion control valve: a valve on the cold inlet that releases pressure as water heats, sparing the relief valve.
  • Anode: a metal rod inside the tank that corrodes so the tank doesn’t.
  • Tempering valve: a valve that blends cold into hot water on its way to the taps it serves.
  • Temperature control device: the general term for a tempering or thermostatic mixing valve.

Hot water maintenance compared with nearby jobs

When the tank itself is leaking and a new system is due, the job becomes hot water system installation. Replacing just the anode to stretch a tank’s life is hot water anode replacement, often done at a service. Gas supply lines, gas leaks and gas appliances other than the heater belong to gas fitting and repairs.

If the hot water has gone cold or the relief pipe won’t stop running, ring DR Smith Plumbing and Roofing on 0483 965 800. Our base is in Clontarf, and we service hot water systems all over the Redcliffe peninsula and the Moreton Bay area.

Water Heater Maintenance and Repair
Call 0483 965 800Request a quote
QBCC 15050088

Common questions

Call if your question is not covered here.

The thermostat stays where it is. The water in the tank is kept hot on purpose, and storage systems must heat to at least sixty degrees. A temperature control device mixes in cold water on the way to the taps it serves. Scalding water at the basin means that device needs checking, or the system may not have one. We find out which.

A storm can cut the power, and a power cut or a tripped circuit leaves an electric system cold. We check the supply first. The switchboard and the heater’s covers stay closed while that happens, because electrical repairs are for a licensed electrician. If the water is still cold next morning, call.

A service every five years by an appropriately licensed person is generally recommended, and more often on bore or rainwater. The maker’s owner’s guide sets the exact schedule. In between, the relief valve lever is lifted every six months, and we do that at each service. Skipping it can lead to the cylinder failing.

It’s the drain line from the relief valve. A small amount while the water heats is expected, because water expands. Steady flow for long periods, often at night, may mean mains pressure is rising above the heater’s design pressure. The drain is never blocked. We check the pressure and the valve and replace whichever is at fault.

Not if the leak is through the wall of the tank. Once the steel has rusted through, the system needs replacing. A leak from a fitting, valve or element seal usually can be repaired. If it’s heavy, close the cold water isolation valve on the pipe going in, keep clear of the tank, and call.

Where we work

DR Smith Plumbing and Roofing is based in Clontarf on the Redcliffe peninsula and works across the Moreton Bay area. For Water Heater Maintenance and Repair in Clontarf or one of the suburbs below, call 0483 965 800. The same number covers plumbing and roofing jobs.

Map of our Clontarf base. Opens Google Maps

Click map view in Google maps

Roofing services

Steel roof repairs, re-roofing and gutters from the team you already call for plumbing, based in Clontarf.

See all roofing services

SPEAK TO US TODAY!

We look after both your plumbing and your roofing, so there is one number to call for either job: 0483 965 800.