Hydronic Heating Systems Installation
A hydronic heating loop
A hydronic heating loop

A hydronic heating system warms a house by pumping heated water through a sealed loop of pipes to radiator panels on the walls or to pipes laid in the floor slab. The water is heated by a gas boiler, an electric heat pump or solar collectors with a backup. This page covers how it works, where Queensland’s climate suits it, and which licensed trade does which part.

Hydronic heating key facts

  • A hydronic system circulates hot or cold water or other fluid through radiator panels in rooms or under the floor, and we design and fit the whole circuit.
  • Heat pumps, solar collectors and gas are the usual heat sources. Hydronic systems are typically more expensive to buy and install than space heaters.
  • Moreton Bay, Brisbane and Ipswich are in climate zone two under the building code, and Toowoomba and the Southern Downs are in zone five.
  • The plumbing and drainage licence includes heating systems in its scope of work.
  • The mechanical services licence covers gas or hot-water heating systems but excludes work on a detached dwelling, and connecting a system to a water supply is not mechanical services work.
  • Only a licensed gasfitter can carry out gas work in Queensland, and gas appliances should be checked and serviced periodically by one.

Signs a hydronic system needs attention

  • The pressure gauge on the boiler reads lower than usual, or keeps falling.
  • Gurgling or knocking comes from the pipes or radiators.
  • A fault code shows on the boiler or heat pump display.
  • Some rooms or zones warm up while others stay cold.
  • Water sits under a radiator, at the manifold or below the relief valve outlet.
  • There is a smell of gas near a gas boiler.

How a hydronic system works

There are four main parts. The heat source warms the water, and a circulating pump moves it around a sealed loop of pipes. The emitters, radiator panels or pipes in the slab, release the heat into the rooms. Thermostats and zone controls decide which parts of the house run and when.

Because the loop is sealed and under pressure, it carries its own safety parts. One boiler maker’s manual lists a pump, a pressure relief valve, an expansion vessel and a pressure gauge, all supplied with the boiler. The normal gauge reading is one to one point two bar, and the safety valve may open at around three bar.

The loop is filled from the house supply. In that manual the heating water is treated against scale and other deposits.

Where hydronic heating suits Queensland homes, and where it doesn’t

Climate is the first question. Moreton Bay, Brisbane, Ipswich and the Lockyer Valley are in climate zone two, warm humid summers and mild winters. For that zone the main design aims are removing the need for heating in winter and reducing cooling, and installing auxiliary heating is advised against.

Average July minimums run about nine and a half degrees at Brisbane Airport and about one degree at Stanthorpe. Toowoomba, the Southern Downs and the South Burnett are in zone five, where the aim is to reduce both heating and cooling. Even within zone two, heating needs rise in more southerly and inland areas.

The type of emitter matters as much. In-slab heating is installed during construction or renovation, and is slow to warm and cool. That makes it unsuitable where heating is needed only occasionally, for short periods or in changeable weather. For zone five, the slab is insulated underneath if in-slab heating is used.

Who does which part of a hydronic job

This table sets out the rule for each part of the system, not a ruling on any particular job.

Part of the system Work involved The rule
Gas boiler and gas supply Gas pipe, connection, commissioning and servicing Only a licensed gasfitter can carry out gas work
Wiring for the boiler, heat pump, pump and controls Hard-wired electrical connections Hard-wired appliances must be connected by a licensed electrician
Refrigerant circuit on a heat pump Joining or opening refrigerant pipes, as on a split unit Anyone who handles refrigerant must hold a refrigerant handling licence
Fill connection to the house supply The pipe and valve that fill the loop, with backflow protection The Plumbing and Drainage Act counts a pipe carrying water within premises as plumbing, and a testable backflow device, if fitted, is notifiable work
Heating loop, radiators and slab pipes Pipework, pressure testing and filling The plumbing and drainage licence scope includes heating systems; mechanical services covers gas or hot-water heating but not work on a detached dwelling, so we confirm the licence class with the QBCC before work starts

What one boiler manual says about faults

This boiler manual gives these causes for the usual faults.

  • Pressure loss: frequent pressure drops point to a possible leak, and we trace it.
  • Noise: the first check is for air in the system, then the system pressure and the charge in the expansion vessel.
  • Overheat trips: frequent trips are put down to a lack of water, poor circulation or a blocked pump, and the checks include radiator valves left closed.
  • Low pressure code: a fault code appears when the boiler can’t detect enough water pressure in the heating circuit to run correctly.
  • Condensate siphon: in this boiler, dirt or combustion deposits can block the trap that drains condensate.

In frosty country, the anti-freeze function works only while the boiler has power and gas, so both stay on through a cold spell. Pipes must be insulated where the temperature falls below zero.

What makes a hydronic job bigger or smaller

  • In-slab pipes go in while a slab is being built or renovated, so an existing home usually means radiator panels.
  • A gas boiler brings a gas supply, and with it a licensed gasfitter.
  • A split heat pump adds refrigerant work, which requires a refrigerant handling licence.
  • Outside walls behind the panels that need insulating add to the work.

What to know before we arrive

The law comes first, and for hydronic heating it is split between trades. In Queensland, only a licensed gasfitter may do gas work, and hard-wired equipment must be connected by a licensed electrician. The Plumbing and Drainage Act counts a pipe carrying water within premises as plumbing, and most plumbing work requires a licensed plumber or drainer, which is what we are.

The plumbing and drainage licence scope includes heating systems. Mechanical services covers gas or hot-water heating systems but excludes work on a detached dwelling, and connecting a system to a water supply is not mechanical services work. Neither description uses the word hydronic, so we confirm which licence class applies to the loop with the QBCC before work starts.

While you wait for us, your part is to watch and report. Note the reading on the pressure gauge and any fault code on the display, and look under radiators and around the manifold for water. We handle the fill valve, the radiator bleed valves and the boiler covers. The loop is sealed and under pressure, and its water can be hot.

If you smell gas, don’t light anything or switch electrical devices on or off, and open doors and windows. If you can still smell gas after turning off the gas supply, call triple zero. Those are the standard Queensland gas safety steps.

Worth noting before we visit:

  • The make and model of the boiler or heat pump, from its label.
  • The gauge reading, and any fault code.
  • Which rooms or zones are cold, and since when.
  • When it was last serviced, and by whom.

A gas system compliance certificate is issued when an installation is completed, and the original goes to the owner or operator. Where treatments are used, the boiler manual requires a backflow device or an air break, and we say which one suits. If a testable backflow prevention device is fitted at an existing building, the Regulation lists that as notifiable work, so we register it on a Form 4.

To close on the law: gas work belongs to a licensed gasfitter, hard-wiring to a licensed electrician, and plumbing, as the Act defines it, to a licensed plumber. The loop itself falls under the plumbing and drainage licence scope, and the licence class is confirmed before work starts.

Hydronic terms you’ll hear

  • Boiler: the appliance that heats the water in a gas hydronic system.
  • Emitter: the part that gives off heat in the room, either a radiator panel or pipes in the slab.
  • Expansion vessel: a sealed tank on the loop that takes up the extra volume as the water heats.
  • Manifold: the set of valves where the pipes for each slab loop or zone start and finish.
  • Bleeding: letting trapped air out of a radiator through its air vent valve.
  • Zone: a part of the house heated on its own thermostat.

Hydronic heating compared with nearby jobs

A heating-only boiler keeps the hydronic loop separate from the hot water at the taps, so a new tank for showers and taps is hot water system installation. Gas supply lines and gas leaks are covered under gas fitting and repairs. Any backflow device that keeps treated heating water out of the drinking supply is explained under backflow prevention and testing.

For water pipes, drains and hot water at your place, call DR Smith Plumbing and Roofing on 0483 965 800. We’re based in Clontarf, on the Redcliffe peninsula.

Hydronic Heating Systems Installation
Call 0483 965 800Request a quote
QBCC 15050088

Common questions

Call if your question is not covered here.

The guidance for our climate is cautious. Moreton Bay and Brisbane are in climate zone two, where the main design aim is to remove the need for winter heating, and auxiliary heating is advised against. Toowoomba and the Southern Downs are in zone five, where reducing heating is one of the aims.

More than one trade. Only a licensed gasfitter can carry out gas work, and hard-wired equipment must be connected by a licensed electrician. Refrigerant work on a heat pump requires a refrigerant handling licence. The water pipework falls under the plumbing and drainage licence, and we confirm the class with the QBCC.

Frequent pressure drops point to a possible leak in the system. We look under radiators, at the manifold and below the relief valve outlet for water. Until we arrive, note the gauge reading each morning. Topping up is ours to do.

Radiator panels can, because they mount on the walls with pipes run to each one. In-slab heating is harder, since it is installed during construction or renovation. The outside walls behind panels must also be well insulated, so an older house may need insulation work as part of the job.

To the maker’s schedule for your boiler or heat pump. The boiler manual above recommends a service every twenty-four months, with combustion and efficiency checks to AS/NZS 5601. Gas appliances should be serviced periodically by a licensed gasfitter. Between visits, keeping an eye on the gauge is your part.

Where we work

DR Smith Plumbing and Roofing is based in Clontarf on the Redcliffe peninsula and works across the Moreton Bay area. For Hydronic Heating Systems Installation in Clontarf or one of the suburbs below, call 0483 965 800. The same number covers plumbing and roofing jobs.

Map of our Clontarf base. Opens Google Maps

Click map view in Google maps

Roofing services

Steel roof repairs, re-roofing and gutters from the team you already call for plumbing, based in Clontarf.

See all roofing services

SPEAK TO US TODAY!

We look after both your plumbing and your roofing, so there is one number to call for either job: 0483 965 800.